Linear Hall Sensor Elements – Technical Overview
Explore the technologies, applications and selection criteria of our GaAs and InSb Hall effect elements. Choose a section below to view the corresponding product information and comparison tables.
GaAs Hall Effect Elements – Technology & Product Selection
GaAs Hall Effect Elements
GaAs Hall effect elements are four-terminal magnetic sensing components that convert magnetic flux density into a proportional Hall voltage. The product family combines high linearity, good temperature stability, low power requirements and compact package dimensions.
Most models are ion-implanted magnetic sensing elements made of monocrystalline gallium arsenide semiconductor material. CYSJ2A, CYSJ3A and CYSJ15A use an AlGaAs/InGaAs/GaAs two-dimensional electron gas (2DEG) heterojunction structure fabricated by molecular beam epitaxy, providing particularly high magnetic sensitivity at a low excitation current.
Different models are available with surface-mount, DFN or leaded packages, different sensitivity and resistance ranges, and different temperature capabilities. Selected ultra-high-sensitivity models offer a measuring range from 0.1 µT to 3 T and an operating temperature range from −100 to +200°C.
Typical Applications
- Magnetic field measurement
- Current and power sensing
- DC brushless motor commutation and control
- Non-contact switching
- Position detection and control
- Rotational speed and RPM detection
- Low-temperature magnetic measurement with selected models
Selection Considerations
The most suitable GaAs Hall effect element should be selected according to the required Hall-voltage level, excitation method, input and output resistance, offset voltage, operating temperature and package configuration.
Surface-mount and DFN products are suitable for compact PCB assemblies and short sensing distances. Leaded products allow the sensing element to be positioned away from the PCB or closer to the magnetic target. For precision applications, the offset voltage, Hall-voltage temperature coefficient, resistance temperature coefficient and linearity should also be considered.
Product Family Overview
The GaAs Hall effect element portfolio consists of two main technology groups:
Ultra-High-Sensitivity 2DEG Hall Elements
CYSJ2A · CYSJ3A · CYSJ15A
These elements use an AlGaAs/InGaAs/GaAs 2DEG heterojunction structure fabricated by molecular beam epitaxy. They offer very high current-related sensitivity, low excitation-current requirements and low power consumption.
The three models provide different Hall-voltage levels and input resistances, with operation from −100°C to +200°C and SOT-143 or SIP package options.
Ion-Implanted GaAs Hall Elements
CYSJ902 · CYSJ106C · CYSJ106DFN · CYSJ166A · CYSJ302C · CYSJ362A · CYTHS124
Made of monocrystalline GaAs semiconductor material, these Hall elements provide high linearity, stable temperature characteristics and compact package dimensions.
Models differ in Hall-voltage range, input and output resistance, offset voltage, package type and operating temperature. Most operate from −40°C to +125°C, with extended-temperature versions available.
GaAs Hall Effect Elements – Product Selection Guide
Compare individual models by sensitivity, measuring range, resistance, electrical limits and package.
| Part Number | Sensitivity Range (mV/mT) | Linearity | Measuring Range | Input / Output Resistance (Ω) | Max. Supply Current / Voltage | Operating Temperature | Package |
|---|---|---|---|---|---|---|---|
| CYSJ2A | 1.17–1.71 | 0.5% | 3 T | 620–780 / 620–780 | 9 mA / 6 V | −100°C to +200°C | SOT-143, SIP |
| CYSJ3A | 0.96–1.44 | 1.0% | 3 T | 1100–1450 / 1100–1450 | 5 mA / 5 V | −100°C to +200°C | SOT-143, SIP |
| CYSJ15A | 1.04–1.34 | 1.0% | 3 T | 3100–4100 / 3100–4100 | 1.4 mA / 5 V | −100°C to +200°C | SOT-143, SIP |
| CYSJ902 | 1.44–2.16 | 1.0% | 3 T | 650–850 / 650–850 | 13 mA / 12 V | −40°C to +125°C or −55°C to +150°C | SIP |
| CYSJ106C | 1.8–2.4 | 2.0% | 3 T | 650–850 / 650–850 | 13 mA / 10 V | −40°C to +125°C | SMT |
| CYSJ106DFN | 1.8–2.4 | 2.0% | 3 T | 650–850 / 650–850 | 11 mA / 9.5 V | −40°C to +125°C | DFN |
| CYSJ302C | 1.8–2.4 | 2.0% | 3 T | 650–850 / 650–850 | — / 10 V | −40°C to +125°C | SIP |
| CYSJ166A | 3.1–4.1 | 2.0% | 3 T | 1000–1500 / 1800–3000 | — / 12 V | −40°C to +125°C | SMT |
| CYSJ362A | 3.1–4.1 | 2.0% | 3 T | 1000–1500 / 1800–3000 | — / 12 V | −40°C to +125°C | SIP |
| CYTHS124 | 3.1–4.0 | 2.0% | 2 T | 1000–1500 / 1800–3000 | — / 12 V | −55°C to +125°C | SOT-143 |
InSb Hall Effect Elements – Technology & Product Selection
InSb Hall Effect Elements
InSb Hall effect elements are four-terminal magnetic sensing components that convert magnetic flux density into a proportional Hall voltage. The product family combines high magnetic sensitivity, low zero-field offset and compact package dimensions. Different models are available with surface-mount or leaded packages, different sensing levels, different Hall-voltage ranges and different temperature capabilities.
Typical Applications
- Magnetic field measurement
- Current sensing
- Rotational speed detection
- DC brushless motor commutation
- Position detection and control
Product Family Overview
The InSb Hall effect element portfolio consists of two main mechanical groups:
Surface-Mount Hall Elements
CYTY101A · CYSH12AF · CYTY105A · CYTY108A
These models use compact surface-mount packages with four symmetrically arranged terminals. Their input and output terminals are positioned diagonally, allowing the same terminal arrangement after a 180° rotation.
They are suitable for compact PCB assemblies and are available in tape-and-reel packaging.
Leaded Hall Elements
CYTY300B · CYTY302B · CYTY322B · CYTY922B
These models use four-lead packages, allowing the sensing element to be placed at a defined distance from the PCB or near the magnetic target.
They differ mainly in package thickness, sensing level, Hall-voltage range and permitted input current.
InSb Hall Effect Elements – Product Selection Guide
Compare the sensitivity, resistance, maximum supply current, operating temperature and package of individual models.
| Part Number | Sensitivity Range (mV/mT) | Input / Output Resistance (Ω) | Max. Supply Current | Operating Temperature | Package |
|---|---|---|---|---|---|
| CYTY922B | 9.12–14.8 | 240–550 / 240–550 | 10 mA | −40°C to +110°C | SIP |
| CYTY322B | 9.12–14.8 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SIP |
| CYSH12AF | 7.84–16.6 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SOT-143 |
| CYTY101A | 9.12–14.8 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SMT |
| CYTY108A | 7.84–12.8 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SMT |
| CYTY105A | 6.72–10.96 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SMT |
| CYTY302B | 6.72–16.6 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SIP |
| CYTY300B | 7.8–12.8 | 240–550 / 240–550 | 20 mA | −40°C to +110°C | SIP |
Package Types, Hall Voltage and Sensing Levels
The table below shows the package configuration, Hall-voltage range, available ranks and sensing level of each InSb product.
| Product | Package Type | Output Hall Voltage | Available Ranks | Sensing Level | Package / Size |
|---|---|---|---|---|---|
| CYTY101A | Surface-mount | 228–516 mV | E–J | 0.6 mm | SMT / 2.9 × 1.55 × 1.1 mm |
| CYSH12AF | Surface-mount | 196–465 mV | D–I | 0.6 mm | SOT-143 / 2.9 × 1.5 × 1.1 mm |
| CYTY105A | Surface-mount | 168–274 mV | C–E | 0.4 mm | SMT / 2.1 × 1.25 × 0.55 mm |
| CYTY108A | Surface-mount | 196–320 mV | D–F | 0.5 mm | SMT / 2.1 × 1.25 × 0.8 mm |
| CYTY300B | Leaded | 196–320 mV | — | — | SIP / 2.7 × 2.9 × 1.65 mm |
| CYTY302B | Leaded | 168–370 mV | C–G | 0.32 mm | SIP / 2.7 × 2.35 × 0.95 mm |
| CYTY322B | Leaded | 228–370 mV | E–G | 0.42 mm | SIP / 2.7 × 2.35 × 0.95 mm |
| CYTY922B | Leaded | 228–370 mV | E–G | 0.42 mm | SIP / 2.7 × 2.35 × 0.95 mm |
Note: Hall-voltage values are measured at an input voltage of 1 V and a magnetic flux density of 50 mT at an ambient temperature of 25°C.
Output Hall Voltage Rank Classification
The Hall-voltage rank identifies the sensitivity range of an InSb Hall effect element under defined test conditions. The rank is determined at an input voltage of 1 V, a magnetic flux density of 50 mT and an ambient temperature of 25°C.
The rank ranges overlap to provide continuous product coverage and allow the most suitable sensitivity class to be selected for the application.
| Rank | Output Hall Voltage, VH |
|---|---|
| C | 168–204 mV |
| D | 196–236 mV |
| E | 228–274 mV |
| F | 266–320 mV |
| G | 310–370 mV |
| H | 360–415 mV |
| I | 405–465 mV |
| J | 454–516 mV |